Skip to main content
BEAB CERTIFIED · UK INSTALLED

The UK's Infrared Ceiling Heating Specialist

The UK's exclusive supplier of the PowerBoard — the first 230V far-infrared heating system that installs flush into your ceiling void, with zero visible hardware.

Underfloor Heating Supplier

Underfloor Heating Supplier

The film is laid by whoever is doing the floor, so most of our floor work is sold as equipment, not installation. If you have the trades, you do not need ours.

Get FREE Savings Analysis →

BEAB Certified · 10-Year Warranty · 30-70% Savings · Zero Maintenance

Who we supply

Installers and electricians

Specified systems, layout drawings, and a technical contact who answers. Trade pricing from the first job.

Flooring contractors

The heating arrives sized to your floor schedule, ready to lay before the covering goes down.

Builders and developers

Volume pricing across plots, one specification repeated cleanly, and Part L friendly all-electric heating.

Merchants and resellers

Supply agreements for stocking the range, with support material your counter staff can actually use.

Why trades are switching to film

The margin on an underfloor job is decided by labour hours and callbacks, not by the material price. Film wins on both, and that is the honest reason to stock it.

Lays dry, no screed wait

Sheets roll out and plug together, and the covering goes over the top. No wet trades, no screed cure holding the programme, no return visit to finish.

No cable spacing to get wrong

The film heats across its whole surface at a fixed output, so there is no cable run to space, measure or accidentally cross. Less skill risk on site, fewer cold-spot complaints after.

1.4mm means no height problems

Almost nothing added to floor level, so no trimming doors, no threshold ramps, no arguments with the flooring fitter. The usual retrofit blockers simply do not come up.

Fewer callbacks by design

Even surface output and a specified circuit design mean the floor performs the way the drawing says. The commissioning tests are defined, so a signed-off floor stays signed off.

And the story your customer hears from you is easy to stand behind: even warmth, nothing visible, and running costs you can show them from the published figures, worked at 24.5p/kWh with the basis stated.

1.4mm

Added to the floor. No screed, no height build-up, no trimmed doors

160/220

W/m² outputs, specified per room from the heat loss, not guessed

UK & IE

Exclusive distribution, so supply comes direct, not through a chain

The heating film is independently tested to BS EN 60335, the British safety standard for electric heating appliances, and is CE and UKCA marked.

How it connects

Film, sealed T-pieces, a thermostat with a floor sensor, and a standard 220 to 240V supply. No transformer, no manifold, no pipes.

How supply works

We do not sell rolls of film off a shelf, because a floor bought unsized is a floor that disappoints. Every supply job is specified first, and the specification is free.

1. Send the floor

Room dimensions and the intended covering. A sketch or a floor plan is enough, and a cutting schedule is better.

2. We specify and quote

Sheet layout, circuit design, controls and a supply quote, sized to the actual floor rather than guessed by the square metre.

3. Delivered, supported

Equipment delivered UK and Ireland wide with the layout drawings. Technical support stays available through the fit and commissioning.

What we supply

Electric underfloor heating film

1.4mm heating film in 160 and 220 W/m² outputs and three sheet sizes, laid under tile, stone, dense hardwood, and laminate or vinyl where the build-up allows. Waterproof connectors, thermostats and controls supplied alongside.

Infrared ceiling panels

The PowerBoard range, 250W integrated and 500W and 750W surface-mount panels, for the rooms where the ceiling is the better answer than the floor. Same supply model: specified, delivered, supported.

Film order codes

The output is watts per square metre of floor. Pick the series from the room's heat loss, then make the area up from the sheet sizes. Quote the codes when you enquire and the specification goes faster.

Where a trade account leads

A trade account is the first rung, not the deal. Volume moves you up the partner tiers, and the terms improve as you climb.

OPEN A TRADE ACCOUNT

Bronze

Trade pricing, a named technical contact, and specification support on every job from the first one.

REGULAR VOLUME

Silver

Improved terms, priority supply, and marketing support for the work you quote under your own name.

COMMITTED PARTNERS

Gold

The best commercial terms and first call on installation work from PoweRad enquiries in your area.

See the full partner programme for what each tier carries.

Buying more than once? Open a trade account

Trade pricing, priority supply and a named technical contact, and it is the first rung of the PoweRad partner programme, where terms improve as your volume grows.

Supplier questions, answered

Do you supply underfloor heating without installation?

Yes, supply only is most of what we do. We size the floor from your dimensions, specify the sheets, circuits and controls, and deliver the equipment with a layout your own floor layer and electrician work from. A Part P electrician makes the final connection, which is a UK legal requirement.

Who can open a trade account?

Installers, electricians, flooring contractors, builders, developers and merchants. A trade account gives trade pricing, priority supply and a named technical contact, and it is the entry point to the PoweRad partner tiers, which add better terms as your volume grows.

Do you publish trade prices?

No, trade pricing is on application through a trade account. Every job is specified before it is priced, because an underfloor system quoted without sizing the floor is guesswork, and volume changes the numbers.

Where do you deliver?

Across the UK and Ireland. PoweRad holds the exclusive UK and Ireland distribution rights for the system, so supply comes from us directly rather than through a chain of resellers.

Can you produce the specification for us?

Yes, and we would rather you let us. Send the floor dimensions and the intended covering, and we return the sheet layout, circuit design and controls specification before anything ships. The heating film runs at 160 or 220 W/m² and any circuit is limited to 3,500W, so larger floors are split across circuits, which is specification work, not guesswork.

Can the film go in bathrooms and wet rooms?

Yes, wet areas use a fully waterproofed, overmoulded version of the film with additional waterproofing applied during installation, and the thermostat must be IP54 rated and sited in a dry zone. Tell us the room is a wet area when you send the dimensions and we specify the right variant.

What controls do you supply with it?

Every specified system includes thermostats, one per zone, with a floor sensor. Multi-room jobs get per-room control as standard, and for whole-property projects the system integrates with smart control platforms including Loxone for scheduling and zoning across the building.

Do you support installers during the fit?

Yes. Technical support is available from first fix through commissioning, including the insulation resistance testing the system requires before the floor covering goes down. You are not left alone with a pallet and a wiring diagram.

Send us the job and we will price the supply

Dimensions and covering for a one-off floor, or a schedule across plots. The specification is free either way, and we will say so if the system is not the right fit for the job.

Quick Quote Request

Enter your details for a fast callback from our Underfloor Heating Supplier team.